COMMERCIAL · OFFICES & HEADQUARTERS

Comfort at work. Usage under control.

From workspaces to plant rooms, coordinate the building according to schedules, occupancy and the needs of each zone.

Explore the needs ↓
Comfortable office floors, with no unnecessary operation. — generic office illustration

01FOLLOW THE WORKING DAY

Comfortable office floors, with no unnecessary operation.

Coordinate lighting, solar shading and regulation according to the schedules and the zones actually in use.

  • Lighting dimmed according to natural light, if the sensors and luminaires allow it
  • Blinds per façade, with weather priorities and defined local controls
  • Work, reduced and unoccupied modes with timed override
  • Zones separated to keep the necessary services running

Use caseA team stays after hours: it extends comfort in its own zone, without restarting the whole floor.

Explore smart lighting ↗︎
Meeting rooms that are ready, indoor air that is monitored. — generic office illustration

02ADAPT COMFORT TO THE USE

Meeting rooms that are ready, indoor air that is monitored.

Distinguish a booking, a detected occupancy and a technical mode. These pieces of information are not interchangeable.

  • Meeting, presentation and end-of-session scenes
  • Temperature, humidity and CO₂ at the equipped points
  • Adjustable ventilation if the equipment and regulation allow it
  • Alert on lasting exceedance or sensor fault, with validated thresholds

Use caseAn occupied room shows a rise in CO₂: the regulation adapts the ventilation if this is planned, or the team receives a qualified alert.

Explore comfort and air quality ↗︎
From the main meter to the metered zone. — generic office illustration

03MAKE OPERATION EASIER

From the main meter to the metered zone.

Relate consumption to schedules and uses to identify drifts and prepare interventions.

  • Electricity by floor, feeder, use or tenant if sub-metering exists
  • Water in washrooms and service areas: volumes, flows and temperatures if measured
  • Localized technical alarms, history and acknowledgments distinct from resolution
  • Views and rights suited to the operator, the maintenance contractor and the occupants

Use caseA flow persists in the washrooms outside occupancy: an alert is created. A shut-off is commanded only if it belongs to the authorized scenario.

Explore supervision ↗︎

USEFUL DATA, CLEAR SCOPES

Monitor each zone, understand the building.

An overall measurement is not the exact consumption of each office. The points, calculation periods and units remain identified in each view.

ENERGY · kWh / kW

Consumption and power.

Compare the cumulative energy and power demand of the metered feeders. Separate lighting, outlets and HVAC where the architecture allows it. Relate deviations to schedules and conditions of use.

Lighting38 kWhOutlets52 kWhHVAC140 kWhFloor 2 · yesterday · 230 kWh
WATER · m³ / L/min / °C

From services to sectors.

Track the volumes and flows of washrooms, kitchens and other equipped sectors. Distinguish cold and hot water if they are metered separately. An exceeded volume does not, by itself, confirm a leak.

Washrooms floor 11.8 m³ / dayKitchen0.9 m³ / dayHot water55 °CNighttime flow0 L/min
AIR & OCCUPANCY

Qualify before acting.

Track CO₂, humidity and temperature at the measured points. CO₂ does not describe overall air quality by itself. Occupancy data serves the building’s uses, not the individual monitoring of employees.

Room A · CO₂780 ppmRoom B · CO₂1,250 ppm · boosted airHumidity48%Temperature23.5 °C
Operating exampleA floor is consuming after it has closed: schedules, overrides and circuits are checked before acting; a leak or air alarm keeps its own procedure.
20:00Floor 3 closed6 kW still drawnSchedules checkedOverride left active: room BCircuit back on schedule

AN ARCHITECTURE SUITED TO THE EXISTING INSTALLATION

Connect the functions without losing the priorities.

Local controls.

Plan settings that are easy to understand, authorized ranges and timed overrides. Safety functions remain within their dedicated scope.

Room setpoint21 – 25 °COverride2 h maximumLightingschedule at 19:00Fire safetynot controlled

Verified integrations.

KNX, DALI, BACnet or Modbus depending on the products, gateways and licenses selected. A room booking is not presence detection; the link to the software is checked case by case.

Lighting · DALIverifiedAHU · BACnetverifiedMeters · ModbusverifiedBooking softwareto be checked

Identifiable feedback.

Distinguish a command sent from a confirmed status. Display the reading time and link faults; unavailable data does not become a zero value.

09:12Setpoint 22 °C · status 22 °CConfirmed09:14Blind lowered · no feedbackPending09:20Floor 2 meter · linkUnavailable
Example: a room that is booked but emptyThe booking prepares the room; it is the detected presence that decides whether comfort is maintained.
10:00BookingComfort preparedNo presence10:15Still emptyComfort reducedLighting off

Thresholds, time delays, access rights, backups and behavior if communication is lost are defined during the study. No quantified gain is guaranteed without an analysis of the site. Operational sub-metering does not automatically constitute billing-grade metering.

PRODUCTION · CONSUMPTION · SMART MANAGEMENT

Producing is not enough to keep consumption under control.

Occupancy, schedules and vehicle charging: understand the energy balance of the workspaces.

Without suitable metering and control, unnecessary consumption or power peaks can persist, even with local production.

01

PRODUCE & MEASURE

Measure the actual balance.

Distinguish the consumption of equipped uses, any photovoltaic production, grid import and export.

Solar / week35%Self-consumed83%Exported17%
Metering, production and exchanges
02

USE BETTER

Adjust the uses.

Adjust schedules, lighting, HVAC and compatible charging to presence and available power.

Unoccupied zoneReduced comfortSolar surplusCharging favoredPower peakLoad shedding allowed
Optimize according to priorities
03

SUPERVISE

Supervise and verify.

The BMS brings together the accessible balances, flags drifts and coordinates the authorized commands. Local automation and dedicated protections keep their role.

Nighttime consumptiondrift reportedAuthorized commandconfirmed
BMS supervision

Offices and headquarters example. Outside occupancy, the planned zones reduce their comfort; permanent equipment stays powered. Non-urgent charging can be modulated according to priorities.

Local production and storage only if present or planned. Functions depend on the sensors, metering and interfaces available; results to be checked over comparable periods, with no guaranteed savings.

NEW BUILD, RENOVATION OR GRADUAL ROLL-OUT

Our approach, step by step.

  1. 01SurveyWith you

    Zones, schedules, networks, equipment and site constraints.

  2. 02Design3I-DS

    Scenarios, measurements, thresholds, responsibilities and rights.

  3. 03Supply3I-DS

    Controllers, sensors, meters, controls and gateways.

  4. 04Programming3I-DS

    Zones, schedules, supervision, dashboards and alarms.

  5. 05Pilot zone3I-DS + you

    One floor tested — commands, status feedback, faults — before extension.

  6. 06Follow-up3I-DS

    Training, configuration file and adjustments after occupancy.

What you receive
  • Function schedule per zone
  • Points list
  • Pilot zone validated
  • Test report
  • Consumption monitoring dashboards
  • Programming file
  • Operator training

Frequently asked questions

Your questions,
our answers.

Is your question not listed here? Our team will answer and guide you to the right solution.

commercial@3i-ds.com
Who carries out the work?

3I-DS designs the solution, supplies the control equipment, programs it, commissions it and provides follow-up. Depending on the project, we can also install this equipment — screens, sensors, gateways — and take charge of the wiring; otherwise, the site’s installers (electrician, refrigeration technician, plumber) carry it out from our drawings, and we coordinate the tests with them.

Can the existing equipment be kept?

The survey identifies the references, accessible interfaces and adaptations needed. Compatibility is not assumed.

Can a floor or a tenant be monitored separately?

Yes, if the scope is metered and its circuits can be identified. An estimated allocation must remain distinct from a dedicated measurement.

Are the values in the dashboard real?

No. Scenarios, values and feedback are simulated. Consumption is separate for each zone; the commands do not control any real equipment.

Can control be adapted to remote working?

Yes. Schedules, detected presence and room bookings make it possible to reduce heating, air conditioning and lighting in lightly occupied zones.

Can work be carried out in an occupied building?

Yes. The work is organized zone by zone with the site’s contractors, and the programming is tested on a pilot zone before being extended.

YOUR SPACES, YOUR SCHEDULES, YOUR PRIORITIES

A building at the service of those who work there.