Energy
Energy consumed or produced, accumulated over an identified period.
02 · MEASURE · ENERGY
Identify consumption, track uses and spot deviations. A clear view, from the main meter down to the circuit.
Explore the solutions ↓FROM METERING TO ANALYSIS
A single overall reading is not always enough to understand a building. A metering plan spreads the measurements by switchboard, zone or use to give meaning to consumption.
The goal: comparable data, with the right units, consistent periods and a clearly identified scope.

01MEASURE IN THE RIGHT PLACE
A main meter for the site, sub-meters for switchboards and major loads: every kWh is linked to a zone or a use.
Use case Compare the main switchboard and the sub-boards to find out how much each zone weighs in the site’s consumption.
Discuss this need ↗︎
02GO DOWN TO THE LEVEL OF USES
Go down to feeder level: lighting, ventilation, air conditioning, outlets, kitchen or server room.
An essential distinction A current sensor measures amperes. To obtain kWh, voltage and power factor are also needed: that is the role of the power meter.
Discuss this need ↗︎
03UNDERSTAND THE DEVIATIONS
History, comparisons and indicators to spot the uses that deserve action.
Use case A nighttime baseload appears on the curve: it is compared with the schedules and the equipment left running.
Discuss this need ↗︎04 / COLLECT AND SHARE
Meters communicate over Modbus, M-Bus or pulses with a data collection unit, which feeds the dashboards and the BMS.
Depending on the project, this unit also provides the monitoring interface; integration is checked on the equipment selected.
INDICATORS WITHOUT CONFUSION
Energy consumed or produced, accumulated over an identified period.
The level of active power at a given moment.
Electrical quantities that are distinct from energy.
Read by a communicating water meter.

06TRACK PHOTOVOLTAIC PRODUCTION
Inverters, meters and battery brought together over a common period to read the site’s actual balance.
Example without storage 20 kW produced supply 15 kW of consumption; the remaining 5 kW are exported to the grid if the connection allows it. This is an instantaneous balance, not a daily energy figure.
The balance relies on a bidirectional meter at the grid connection point and on the inverter interfaces.
Move from metering to coordinating uses ↗︎INDICATORS TO DEFINE
Three measurement points: production, the grid connection point and consumption by the loads. The grid meter alone is not enough.
Share of production consumed on site, calculated over a given period. With a battery, direct consumption, storage and losses are distinguished.
Share of consumption covered by local production. A state of charge in % indicates neither the kWh available nor a backup duration.
kWp: installed panel power · kW: measured power · kWh: cumulative energy. The design and grid connection of the photovoltaic installation are covered by a separate scope.
BATTERIES · MEASUREMENTS AND LIMITS
State of charge in %, charge and discharge power in kW, cumulative energy in kWh.
Temperatures, alarms and state of health reported by the battery management system.
Charge, discharge and reserve follow the optimization strategy; the battery management system and the inverter keep their limits and protections.
TRACK AND QUALIFY EVENTS
Before concluding there is a production fault, the equipment, the communication and the conditions at that moment are checked.
Codes and statuses of inverters, meters and batteries, with the site, the device, the time and the priority.
Equipment stopped, zero production or link down: three distinct cases. An unavailable value is never displayed as zero.
A drop is read alongside sunlight, temperature and shading. Without a reference sensor, a deviation remains a lead, not a diagnosis.
Recipients, thresholds and acknowledgments are defined with the operator. Notifications do not replace local protections.
FROM THE LOCAL SITE TO THE CENTRAL VIEW
A central view brings all the sites together, with the detail of each installation one click away.
Production, consumption, exchanges and storage per site, with the freshness of each data point.
Installed power, weather and availability differ from one site to another: ratios are compared, not raw kWh.
Rights by role and by site, link alarm, local collection and history recovery after an outage.
Central supervision replaces neither local automation nor protections. Remote access is validated with the IT managers.
Link monitoring to technical supervision ↗︎INTERFACES · PROTOCOLS · RIGHTS
The choice is made on the references, versions and documentation of the equipment.
Addresses, registers, units and scale factors are checked point by point. Reading and writing are validated separately.
Common data models over Modbus for compatible inverters and meters; we check which ones the device actually implements.
Data exposed, authentication, request limits, local or cloud access. Many APIs are read-only.
In multi-site setups, the link is secured and segmented: no equipment interface is exposed directly to the Internet. Loss of communication and recovery are tested before commissioning.
FROM METERING PLAN TO FOLLOW-UP
Zones, uses and indicators to track; the operator’s objectives.
Existing switchboards, ratings, diagrams and meters.
Measurement points, meter type and protocol for each feeder.
Meters, power meters, current transformers and collection unit.
Collection, dashboards, thresholds and reports; consistency check of meter readings.
Training, first reports and threshold adjustment with the operator.
Frequently asked questions
Is your question not listed here? Our team will answer and guide you to the right solution.
commercial@3i-ds.comDepending on the project, 3I-DS can install the meters and current transformers in the switchboards and take charge of their wiring, or rely on the electrical contractor. 3I-DS designs the solution, supplies the equipment, configures the collection and checks the measurements.
Yes, if they have a communication output (Modbus, M-Bus or pulses) and sufficient accuracy. The survey confirms this meter by meter.
No: measuring reduces nothing by itself. Monitoring shows where to act — schedules, settings, equipment — and then checks the effect of the actions.
Yes, by applying the tariffs and time bands of your contract to the kWh. The amount remains an estimate: the supplier’s bill prevails.
Yes, with pulse or M-Bus meters connected to the same collection unit.
Communicating meters suited to each use: electricity over Modbus or M-Bus, water and gas via pulses or M-Bus, with current transformers for existing feeders.
Generally every 5 to 15 minutes for consumption, more often for power values to be monitored. The interval is set according to the use and the storage capacity.
Yes, as CSV-type files or periodic reports, for your internal reports, an energy audit or an engineering consultant.
FROM NEEDS TO SOLUTIONS
Find the operating needs that the Energy metering & monitoring solution can address, depending on the project scope.
Rooms, common areas and technical services controlled according to occupancy.
Office floors, meeting rooms and occupancy schedules, with consumption monitoring.
Multi-site branches: schedules, technical alarms and remote supervision.
Villas and residences: comfort, scenes and everyday technical safety.
Greenhouses, irrigation and pumping monitored according to crops and seasons.
Workshops and utilities: metering, alarms and schedules outside process constraints.
Technical rooms: temperatures, power supplies and alarms monitored continuously.
Classrooms, lecture halls and campuses: schedules, presence and user comfort.
Functions are defined during the study: equipment, interfaces, control rights and local priorities must be checked. These links do not imply universal compatibility.
START WITH THE RIGHT MEASUREMENT POINTS