07 · PREVENT

Monitor water. Anticipate anomalies.

Measure consumption, detect the presence of water at monitored points and organize the alerts and actions planned for the building.

Explore the solutions ↓

UNDERSTAND, DETECT AND ORGANIZE THE RESPONSE

Useful information before the intervention.

Metering tracks volumes and, if the device allows it, flow rates. A leak sensor detects the presence of water at its location. Technical alarms inform the teams about specific situations.

These functions are complementary. The values in the demo are illustrative; thresholds, recipients and any shut-offs are defined for each network.

Illustration of water sub-meters on separate outlets

01MONITOR CONSUMPTION

Count the volumes, understand the uses.

Communicating meters by building, by zone or by use: every m³ is linked to a point of consumption.

  • Meter readings and consumption in m³
  • Instantaneous flow in L/min or m³/h
  • History and comparisons by period
  • Unusual flows identified outside occupancy

Use case A persistent flow at night triggers a check. It indicates an anomaly to analyze; it does not locate a leak by itself.

Discuss this need ↗︎

MEASURE BY NETWORK, BY SECTOR AND BY PERIOD

Cold water and hot water: uses to monitor separately.

Each outlet is identified so that volumes, flows and temperatures can be compared. Meters and sensors are chosen according to the fluid and its temperature.

COLD WATER · CW

Understand consumption.

Track volumes by zone and by use: washrooms, kitchens, services or irrigation. Compare days, weeks and months to spot variations.

  • Meter reading and volume consumed over the period
  • Instantaneous flow and flow duration
  • Consumption target per sector
  • Detection of a persistent flow during periods of absence
DOMESTIC HOT WATER · DHW

Combine volume and temperature.

Meter hot water separately from cold water and track its temperature at the key points of the network.

  • Hot water consumption in m³
  • Temperature measured in °C, point by point
  • Production outlet, distribution and loop return
  • History of deviations from the validated setpoints
OVERALL & SECTOR VIEW

Go from the total to the outlet concerned.

Present a summary of the network and the detail of the sectors. A main meter remains a separate measurement from the sum of the sub-meters.

  • Comparison of equivalent periods and uses
  • Split between cold water and hot water
  • Main / sector reconciliation over the same scope and period
  • Missing or inconsistent data flagged separately

A gap between the main meter and the sub-meters may come from unmetered outlets or a reading time lag: it is not proof of a leak. The demo at the top of the page shows a simulation.

Review the metering of my networks ↗︎
Illustration of a floor-level leak sensor near a water connection

03MONITOR EXPOSED LOCATIONS

Detect water where the risk exists.

Sensors placed at sensitive points: under a sink, near a water heater, in a plant room or under a raised floor.

  • Spot sensors or sensing cables, depending on the area to cover
  • Detection zone or point identified in the alert
  • Reported to KNX, a controller or the supervision system
  • Monitoring of the link and of sensor faults

A layout to study One sensor does not cover a whole room: its location depends on the path the water takes and on the technology selected.

Discuss this need ↗︎
Illustration of a motorized shut-off valve on an accessible water network

04ACT ACCORDING TO A VALIDATED SEQUENCE

Shut off the water when the scenario calls for it.

A solenoid valve or motorized valve closes the sector concerned as soon as a leak is confirmed.

  • Valve and actuator sized for the network
  • Time delay, conditions and priorities validated with the operator
  • Position feedback: closure is confirmed, not assumed
  • Manual check and reset before reopening

Use case A sensor detects water: the alert is sent, then the sector valve closes. Water is restored only after an on-site check.

The networks that must never be shut off — fire, process, critical sanitary uses — are identified during the study.

Discuss this need ↗︎
Illustration of a pumping installation with tank level and monitoring cabinet

05REPORT TECHNICAL INFORMATION

Qualify the alert to prepare the intervention.

Statuses and faults of the water equipment brought together in one view: the point concerned, the event and the expected action.

  • High and low levels of tanks and cisterns
  • Statuses and faults of pumps and booster sets
  • Network pressure and technical contacts
  • Event history and acknowledgment

Use case A pump fault is reported with the name of the equipment and its location. The operator checks the status and prepares the intervention.

Discuss this need ↗︎

VOLUMES, FLOWS AND TEMPERATURES

Useful thresholds, explicit alarms.

Each measured point has its limit, its confirmation time, its time window and its recipient.

Thresholds set with the operator, site by site
Information monitoredRule to defineAlert and handling
CW or DHW volume · m³Daily or monthly target per network or sector.Warning when approaching the limit, then exceedance alarm.
Flow · L/min or m³/hFlow above a limit for a given time, or flow outside occupancy.Report with sector, flow, duration and time; usage check.
Cold water temperature · °CHigh threshold at the measured point, with a time delay.Alert and review of the history; network check.
Hot water temperature · °CLow and high thresholds depending on the point: production, outlet or loop return.Out-of-range point identified and operator notified.
Presence of water · sensor statusLocalized detection and confirmation time.Alert, sensor identified, then sector closure if the scenario calls for it.
Tank levelHigh and low thresholds.Alert and planned sequence with the pumps.
Measurement or valve faultMissing data, invalid value or valve not following the command.Separate technical alarm; a missing measurement is never displayed as zero.

Temperature thresholds are validated with the technical managers. Supervision replaces neither local protections nor sanitary checks.

FROM DEVIATION TO DECISION

Alert at the right time, without multiplying false alarms.

01 · CONFIRM

Qualify the exceedance.

Time delay and hysteresis avoid false alarms: a brief peak is not treated like a deviation that lasts.

30 s peakignoredContinuous flow for 2 hdeviation confirmed
02 · INFORM

Send an alarm that can be acted on.

Sector, network, measurement point, value, threshold and time: everything needed to intervene.

03:10Sector B · 6 L/min · outside occupancyAlarm
03 · ACT & VERIFY

Apply the planned action.

Overconsumption remains an alert; a shut-off requires a validated rule. After a leak: acknowledgment, reset, then reopening.

Overconsumptionalert onlyLeak detectedvalve closedReopeningafter acknowledgment
Example scenarioA sector’s volume approaches the target: a warning is sent. A sensor then detects water: the alarm is localized and the valve closes after the time delay.
18:00Limit approachedWarning18:40Sensor wetAlarm localizedSector valve closed
Define my thresholds and alarms ↗︎

FROM THE MONITORED POINT TO THE OPERATOR

A coherent information chain.

Measurements and contacts are collected, processed according to the site’s rules, then sent to the right people through the chosen channel.

Alert sent, acknowledgment and resolution of the cause are three distinct steps, tracked with the site managers.

See BMS & supervision ↗︎
MEASUREMENTS & DETECTIONMeters · sensors · technical contacts
COLLECTION & PROCESSINGRules · zone identification · history
InformViews and notifications
InterveneTeam and procedure
ActSector shut-off

EACH PIECE OF INFORMATION HAS ITS UNIT OR ITS STATUS

Read the data without confusion.

m³

Cumulative volume

A meter reading or consumption calculated over a defined period.

L/min

Instantaneous flow

A volume per unit of time; not to be confused with cumulative consumption.

Dry / water

Localized detection

A sensor status, which is not a flow measurement.

Open / closed

Valve position

The valve’s position feedback, distinct from the command sent.

TARGET THE USEFUL LOCATIONS

Where should monitoring be planned?

HOMES AND RESIDENCES

Water points and appliances.

Under sinks, laundry rooms, water heaters and washing machines.

  • Sensor under the sink
  • Sensor at the base of the water heater
  • Sensor behind the washing machine
HOSPITALITY AND COMMERCIAL BUILDINGS

Zones and plant rooms.

Washrooms, service risers, service rooms and server rooms.

  • Sensor at the base of the riser
  • Sensor under the washrooms
  • Sensor in the server room
TECHNICAL INSTALLATIONS

Tanks and pumping.

Levels, pump faults and break tanks.

  • Tank level
  • Outlet meter
  • Pump fault

Suggested detection point. The exact layout is defined on the drawings, with the plumber.

FROM SURVEY TO MAINTENANCE

Our approach, step by step.

  1. 01SurveyWith you

    Networks, meters, sensitive points and uses that must never be shut off.

  2. 02Design3I-DS

    Sensors, valves, thresholds, recipients and shut-off scenarios validated.

  3. 03Supply3I-DS

    Communicating meters, sensors, motorized valves and collection modules.

  4. 04Programming3I-DS

    Thresholds, alerts, shut-off scenarios and monitoring views.

  5. 05Testing3I-DS + you

    Each sensor and each valve tested with the installer: alert, closure, reopening.

  6. 06Follow-up3I-DS

    Training, periodic sensor tests and threshold adjustment.

What you receive
  • Plan of meters and valves
  • List of alarms
  • Configured leak thresholds
  • Shut-off test report
  • Reopening procedure
  • Configuration file
  • Operator training

Frequently asked questions

Your questions,
our answers.

Is your question not listed here? Our team will answer and guide you to the right solution.

commercial@3i-ds.com
Who installs the valves and meters?

The plumber installs meters and valves on the networks. Depending on the project, 3I-DS can install the sensors and control equipment and take charge of their wiring; otherwise, the electrician does it. 3I-DS designs the solution, supplies the equipment, programs the scenarios and carries out the tests.

Does the meter detect every leak?

No. It reveals an abnormal flow, especially outside occupancy, but does not say where. Location relies on the sensors and on sector-by-sector metering.

Is the water shut off automatically in every case?

No. It happens only on the sectors and under the conditions validated with the operator; some networks are never shut off.

How is water restored after an alert?

After an on-site check: acknowledgment of the alarm, reset of the sensor, then reopening of the valve according to the agreed rule.

Can existing meters or contacts be kept?

Yes, if they have a pulse, M-Bus or Modbus output. The survey checks this device by device.

Do these alerts replace a dedicated safety system?

No. They complement operation; fire safety and equipment protections keep their own devices.

How is a leak detected?

By two complementary means: floor sensors in at-risk rooms, and flow analysis, for example consumption that never stops at night.

Can irrigation and the pool be monitored?

Yes, with dedicated meters and status contacts. Irrigation can also be suspended in case of rain or a detected leak, according to the rules validated together.

Does the building’s water have to be shut off during the work?

Installing the valves and meters requires a short shut-off, organized by the plumber. Programming and testing are then done without any prolonged interruption.

MONITORED POINTS, PLANNED RESPONSES

Which zones would you like to monitor better?