Maintain comfort.
Comfort setpoint applied; the occupant adjusts it within the authorized range.
05 · REGULATE
Coordinate temperature, air renewal and filtration, with measurements suited to each zone and to the building’s uses.
Explore the solutions ↓
COMFORT, REGULATION AND OPERATION
A meeting room, a hotel room and an open-plan office do not have the same schedules or the same needs. HVAC regulation organizes setpoints, commands and status feedback at the level of each zone.
The demo illustrates a regulation loop and possible scenarios. Actual temperatures, flow rates and sequences are defined according to the equipment and the site’s constraints.

01REGULATE CLOSE TO THE USE
Each room or zone has its sensor, its setpoint and its terminal unit: fan coil, radiator valve, underfloor heating or air-conditioning unit.
Use case A hotel room switches to comfort mode when the guest arrives and returns to reduced mode when they leave. The guest adjusts the setpoint within the range set by the operator.
Discuss this need ↗︎
02PRODUCE AND DISTRIBUTE
Heating and cooling production follows the actual demand of the zones; the circuits distribute at the right temperature, at the right time.
Point to watch Underfloor heating responds over several hours, a fan coil within a few minutes. Restart times and time delays are set for each type of emitter.
Discuss this need ↗︎
03CONTROL AIR HANDLING
The AHU supplies fresh air at the right temperature and flow rate; its fans, dampers and coils follow schedules and occupancy.
Use case In mid-season, cooler outdoor air cools the premises without mechanical cooling. During occupancy, the planned fresh air flow rate is maintained.
Discuss this need ↗︎
04INDOOR AIR QUALITY
Air quality is controlled like temperature: it is measured, ventilation is adjusted and the history is kept.
Use case A meeting room fills up: CO₂ rises, ventilation switches to boosted flow, then returns to nominal flow once the room is empty.
CO₂ reflects occupancy-related ventilation; it does not sum up air quality by itself. Sensor location and filter maintenance matter as much as the measurement.
Review the air quality of my spaces ↗︎
05CONNECT AIR CONDITIONING TO THE BUILDING
A gateway connects the indoor units to the building: they are controlled from the room controls or from the supervision system.
To check before integration Brand, range and references of the units, manufacturer’s gateway (KNX, Modbus or BACnet) and the functions actually exposed. A common protocol does not give access to every function.
Discuss this need ↗︎FROM SENSOR TO SUPERVISION
The sensor measures, the controller compares with the setpoint and drives the actuator: valve, fan or damper. Statuses and measurements are then reported to the BMS.
SEQUENCES TO VALIDATE
Comfort setpoint applied; the occupant adjusts it within the authorized range.
Wider setpoints and reduced ventilation; frost protection stays active.
Early start according to the building’s thermal inertia and the outdoor temperature.
The zone’s terminal unit stops after a time delay and resumes when the window is closed.
Summer / winter changeover and dead band: never heating and cooling at the same time in one zone.
Alarm sent and fallback planned; local regulation continues if the network is down.
DIFFERENT QUANTITIES
Room, supply air or circuit measurement; not to be confused with the setpoint.
Volume of air supplied or extracted per hour, measured or calculated by the AHU.
Two distinct indicators. CO₂ does not sum up air quality by itself.
A valve opening is not consumption: energy is measured with a meter.
FROM SURVEY TO FOLLOW-UP
Plant, terminal units, sensors and interfaces in place; comfort needs of each zone.
Setpoints, schedules, sequences and priorities, validated with the operator and the HVAC contractor.
Controllers, sensors, thermostats, valve actuators and VRV / VRF gateways.
Zone regulation, plant and AHU sequences, links with the supervision system.
Zone-by-zone tests with the HVAC contractor: commands, modes, faults and restart.
Training, settings file, then adjustments after one heating and one cooling season.
Frequently asked questions
Is your question not listed here? Our team will answer and guide you to the right solution.
commercial@3i-ds.com3I-DS designs the solution, supplies and programs the regulation: controllers, sensors, thermostats, actuators and gateways. Depending on the project, we can also install this equipment and take charge of its wiring; the machines and networks remain the responsibility of the HVAC and electrical contractors, with whom we coordinate the tests.
Yes, in most cases. A survey of the references and diagrams shows what can be reused, what requires a gateway and what must be replaced.
In principle, no: a dead band separates the heating and cooling setpoints, and the summer / winter changeover is defined according to the installation.
Yes, within a range set with the operator: a few degrees around the setpoint, for a limited time, before returning to the program.
It reduces unnecessary operation, but the result depends on the building and its uses. It is measured through energy monitoring, with no percentage guaranteed in advance.
Chillers, boilers, heat pumps, air handling units, fan coils or VRV systems, as long as they have an accessible interface: contacts, BACnet, Modbus or KNX depending on the model.
Yes, with CO₂, humidity or VOC sensors placed in the zones concerned. Ventilation can then be modulated according to the measurements rather than running at a fixed rate.
The equipment keeps a fallback mode defined at the design stage, and an alarm is sent to the operator. The machines’ own protections always remain active.
FROM NEEDS TO SOLUTIONS
Find the operating needs that the Heating, ventilation & air conditioning solution can address, depending on the project scope.
Rooms, common areas and technical services controlled according to occupancy.
Office floors, meeting rooms and occupancy schedules, with consumption monitoring.
Multi-site branches: schedules, technical alarms and remote supervision.
Villas and residences: comfort, scenes and everyday technical safety.
Technical rooms: temperatures, power supplies and alarms monitored continuously.
Classrooms, lecture halls and campuses: schedules, presence and user comfort.
Functions are defined during the study: equipment, interfaces, control rights and local priorities must be checked. These links do not imply universal compatibility.
COMFORT AT THE PACE OF YOUR SPACES